Recovery - Multipara Patient Monitor

It can be used to monitor adult, pediatric & neonate patient
₹ 50,000.00
Quantity :

Details

  • State of art Central Nursing system.
  • High resolution TFT colour LCD display with touch screen operation.
  • Displays ECG, NIBP, SPO2, TEMP, HR & Waveforms of ECG, Resp & Plethysmograph.
  • Wireless digital two way telemetry communication between central station & bedside monitor.
  • Facility to monitor 8 bed side monitors simultaneously.
  • Integrated 3 line thermal printer.

ECG :

  • Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
  • Lead selection: I, II, III, avR, avL, avF, V,
  • Waveform: 2 ch Lead mode: 3 Leads ( R, L, F or RA, LA, LL)
  • Lead selection: I, II, III,
  • Waveform: 1 chGain: ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, auto

Resparation:

  • Method: Impedance between R-F (RA-LL)
  • Differential Input Impedance: >2.5 MΩ
  • Measuring Impedance Range: 0.3~5.0Ω
  • Base line Impedance Range: 0 – 2.5 KΩ
  • Bandwidth: 0.3 ~ 2.5 Hz
  • Resp. Rate
  • Measuring and Alarm Range
  • Adult: 0 ~ 120 rpm
  • Neo/Ped: 0 ~ 150 rpm
  • Resolution: 1 rpm
  • Accuracy : ±2 rpm
  • Apean Alarm: 10 ~ 40 S

NIBP :

  • Method: Oscillometric
  • Mode: Manual, Auto, STAT
  • Measuring Period in STAT Mode: 5 Min
  • Pulse Rate Range: 40 ~ 240 bpm
  • Alarm Type: SYS, DIA, MEAN
  • Measuring and alarm range
  • SYS: 40 ~ 270 mmHg
  • DIA: 10 ~ 215 mmHg
  • MEAN: 20 ~ 235 mmHg
  • Pediatric Mode
  • SYS: 40 ~ 200 mmHg
  • DIA: 10 ~ 150 mmHg
  • MEAN:20 ~ 165 mmHg
  • Neonatal Mode
  • SYS: 40 ~ 135 mmHg
  • DIA:10 ~ 100 mmHg
  • MEAN:20 ~ 110 mmHg
  • Resolution Pressure:1mmHg
  • Accuracy Pressure Maximum Mean error: ±5mmHg
  • Maximum Standard deviation: ±8mmHg
  • Adult Mode: 297±3 mmHg
  • Pediatric Mode: 240±3 mmHg
  • Neonatal Mode: 147±3 mmHg

SpO2 :

  • Measuring Range: 0 ~ 100 %
  • Alarm Range: 0 ~ 100
  • Resolution: 1 %
  • Accuracy : 70% ~ 100% ±2 %, 0% ~ 69% unspecified
  • Actualization interval: about 1 Sec.
  • Alarm Delay: 10 Sec.

Pulse Rate :

  • Measuring and Alarm Range: 20~300bpm
  • Resolution: 1bpm
  • Accuracy : ±2bpm

Temperature :

  • Channel: 2
  • Measuring and Alarm Range: 0 ~ 50 °C
  • Resolution: 0.1°C
  • Accuracy : ±0.1°C
  • Actualization interval: about 1 Sec.
  • Average Time Constant:<10 Sec.

IBP :

  • Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
  • Measuring and alarm range
  • ART: 0 ~ 300 mmHg
  • PA: -6 ~ 120 mmHg
  • CVP/RAP/LAP/ICP: -10 ~ 40 mmHg
  • P1/P2: -10 ~ 300 mmHg
  • Press Sensor
  • Sensitivity: 5 uV/V/mmHg
  • Impedance: 300-3000Ω
  • Resolution: 1 mmHg
  • Accuracy : ±2% or ±1mmHg, which great
  • Actualization interval: about 1 Sec

Recovery - Multipara Patient Monitor

Add A Review

Your Email Address Will not be Published. Required Fields are Marked.

  • Only registered users can write reviews
  1 star 2 stars 3 stars 4 stars 5 stars
Your Rating

FREE SHIPPING

Free Shipping on World Wide Order Over $99.

TRUSTED PAY

100% Payment Protection & Easy Return

SECURED PAYMENT

All Major Credit & Debit Cards Accepted

SHOP ON APP

Just Download Our App & Shop With Best Offers!